Corrosion Analyses/Corrosive gas tests
Salt spray test chamber SC/KWT 1000
Salt mist and condensation water chamber
Salt mist | Condensation water | Humidifier | |
---|---|---|---|
Max. temperature | +55°C | +45°C | +75°C |
Min. temperature | 5K > TU | 5K > TU | 5K > TU |
TU=+23°C |
SO2 test
Corrosive gas tests are used for the corrosion testing of metals and for determining the speed of aging of plastics and glass. Another important test area is the testing of coatings and casings for tightness.
SO2 (industrial atmosphere) in accordance with DIN EN ISO 6988 / 50018
We have a modular corrosive gas climate simulation system able to implement many standard-compliant test procedures.
Our salt spray test chambers enable reproducible, timely corrosion tests in accordance with relevant national and international standards such as DIN, ISO, EN, IEC, ASTM, DEF, MIL-STD and others.
SO2 test
Salt mist in accordance with DIN 50 021
Process | |
---|---|
1. Phase (8 h) | Moistening of lamps, (40°C, 100 % rel. humidity) Addition of SO2 gas (sulfuric acid produced on test objects) |
2. Phase (16 h) | Adaptation to room temperature (18-28°C, max. 75 % rel. humidity) |
Duration | |
---|---|
1 cycle | 24 h |
5 cycles à 24h | 120 h |
Salt mist in accordance with DIN 50 021
Parameters | |
---|---|
Temperature in chamber | 35°C |
NaCl concentration | 50 g/l = 5 % solution |
Duration max. | 240 h |
Corrosive gas test
Salt mist and condensation water chamber
Corrosive gas tests
in accordance with DIN EN 60068-2-43 Kd | |
---|---|
Width | circa 630 mm |
Depth | circa 630 mm |
Height | circa 670 mm |
Capacity | circa 270 l |
Field for climate tests with corrosive test equipment | +15 °C to +60 °C |
Moisture range | 10 % r. F. to 93 % r. F. |
Water dewpoint | +10 °C to +38 °C |
Special climate point | +25 °C/95 % r. F. |
Contact
Environment Simulation Laboratory
Електронна пошта: s.nasrallah-goldberg@osram.de
Тел.: +49 7324 12-224
Sammr Nasrallah-Goldberg An der Bahnbrücke, 89542 Herbrechtingen